| 您的位置:产品介绍 -> 常规仪器 -> 旋转蒸发器 |
|
LR4003 |
LR4000 |
LR4001 |
LR4010 |
LR4011 |
LR4002 |
- For your protection against splashing water and steam, the operating panel is located below the bath
- All heating baths feature non-slip safety handles to prevent scalding
- Heating bath is constructed of an insulated double wall for your protection against burns and scalding
- Non-sticking vapor tube removes easily eliminating broken glass
- Flask ejector presses off sticking evaporation flasks
- Adjust and fix the height of your evaporation flask in just seconds
- Unique large bore vapor tube offers faster distillation rates
- Long life graphite filled PTFE vacuum seal
- Your choice of manual or motor lift
- Rotary Evaporator with all the general advantages
- Convenient large dial controls for adjustment of rotation speed and heating bath temperature
- Rotation speed from 20 to 270 rpm
- Individual power switches for control panel and heating bath offers additional safety
- One heating bath for water and oil 20 °C - 180 °C
- Digital bath temperature display as standard
- Set bath temperature on display, accuracy +/- 1 °C
- Attachment for optional vacuum valve or Woulff bottle
Upgrade this model with the optional Vacuum controller, VAC control automatic, for automated distillation
|
LR4000
旋转蒸发仪 |
 |
可以方便地调节旋转速度和加热锅温度
旋转速度范围:20-270rpm
手动升降控制
高度调节范围:140mm
加热功率:1300W
控制面板和加热锅有独立的电源开关,提供额外的安全保护
加热锅可兼作水浴和油浴,温度:20℃~180℃
数字设定和显示加热锅温度,精度:±1℃
加热锅材料:不锈钢
加热容积:4.3L
最小蒸发能力:大于1000ml H2O/hr |
- For your protection against splashing water and steam, the operating panel is located below the bath
- All heating baths feature non-slip safety handles to prevent scalding
- Heating bath is constructed of an insulated double wall for your protection against burns and scalding
- Non-sticking vapor tube removes easily eliminating broken glass
- Flask ejector presses off sticking evaporation flasks
- Adjust and fix the height of your evaporation flask in just seconds
- Unique large bore vapor tube offers faster distillation rates
- Long life graphite filled PTFE vacuum seal
- Your choice of manual or motor lift
|
LR4001
旋转蒸发仪 |
 |
|
- Rotary Evaporator with all the general advantages
- Convenient large dial controls for adjustment of rotation speed and heating bath temperature
- Rotation speed from 20 to 270 rpm
- Individual power switches for control panel and heating bath offers additional safety
- One heating bath for water and oil 20 °C - 180 °C
- Digital bath temperature display as standard
- Set bath temperature on display, accuracy +/- 1 °C
- Attachment for optional vacuum valve or Woulff bottle
Upgrade this model with the optional Vacuum controller, VAC control automatic, for automated distillation
- For your protection against splashing water and steam, the operating panel is located below the bath
- All heating baths feature non-slip safety handles to prevent scalding
- Heating bath is constructed of an insulated double wall for your protection against burns and scalding
- Non-sticking vapor tube removes easily eliminating broken glass
- Flask ejector presses off sticking evaporation flasks
- Adjust and fix the height of your evaporation flask in just seconds
- Unique large bore vapor tube offers faster distillation rates
- Long life graphite filled PTFE vacuum seal
Your choice of manual or motor lift
|
LR4002 旋转蒸发仪 |
 |
 |
- Rotary Evaporator with all the general advantages
- Built-in vacuum and vapor temperature controller with 3 programs for automated distillations
- Set your required bath temperature, vapor temperature and vacuum with the user-friendly digital control panel
- Digital display for rotation speed, vapor temperature and bath temperature
- Process timer allows for unattended operations
- One heating bath for water and oil 20 °C - 180 °C
- Includes a vacuum control program, P(const), for solvent separation (control parameter is the pressure)
- P const holds vacuum constant at any time during your distillation with the press of a button
- Includes a vacuum control program for gentle distillation, (control parameter is the vapor temperature)
- T (auto) stops your distillation at a variable minimum pressure
- P (auto) automatically finds required vacuum and holds that level constant (combination from T(auto) and P(const))
- Evacuation can be stopped by the press of a button without opening the vacuum valve
- Start rotation, vacuum control and process timer all together with just one press of a button
- Set and program the 9 most common applications into memory
- Program your required vacuum changes in a ramp
- Attachment for optional vacuum valve or Woulff bottle
- Required accessories: VAC senso T (P/N 591-00350-00) and vacuum valve
|
- For your protection against splashing water and steam, the operating panel is located below the bath
- All heating baths feature non-slip safety handles to prevent scalding
- Heating bath is constructed of an insulated double wall for your protection against burns and scalding
- Non-sticking vapor tube removes easily eliminating broken glass
- Flask ejector presses off sticking evaporation flasks
- Adjust and fix the height of your evaporation flask in just seconds
- Unique large bore vapor tube offers faster distillation rates
- Long life graphite filled PTFE vacuum seal
Your choice of manual or motor lift |
LR4002 旋转蒸发仪 |
 |
 |
内置真空控制器和蒸发点温度控制器、设定蒸发时间
带有3个自动蒸馏程序,可以实现全自动蒸馏
电动升降控制,冷凝管垂直放置
数字控制面板可设定所需的加热锅温度、蒸发温度点和真空度
数字显示旋转速度、蒸发点温度和加热锅温度
内有计时器,只要设定蒸发时间,即使无人也可进行工作
加热锅可兼作水浴和油浴,温度:20℃~180℃
旋转速度范围:20-270rpm
可以方便地调节旋转速度和加热锅温度
高度调节范围:140mm
加热功率:1300W
数字显示加热锅温度,精度:±1℃
加热锅材料:不锈钢
加热容积:4.3L
最小蒸发能力:大于1000ml H2O/hr
|
- Rotary Evaporator with all the general advantages
- Built-in vacuum and vapor temperature controller with 3 programs for automated distillations
- Set your required bath temperature, vapor temperature and vacuum with the user-friendly digital control panel
- Digital display for rotation speed, vapor temperature and bath temperature
- Process timer allows for unattended operations
- One heating bath for water and oil 20 °C - 180 °C
- Includes a vacuum control program, P(const), for solvent separation (control parameter is the pressure)
- P const holds vacuum constant at any time during your distillation with the press of a button
- Includes a vacuum control program for gentle distillation, (control parameter is the vapor temperature)
- T (auto) stops your distillation at a variable minimum pressure
- P (auto) automatically finds required vacuum and holds that level constant (combination from T(auto) and P(const))
- Evacuation can be stopped by the press of a button without opening the vacuum valve
- Start rotation, vacuum control and process timer all together with just one press of a button
- Set and program the 9 most common applications into memory
- Program your required vacuum changes in a ramp
- Attachment for optional vacuum valve or Woulff bottle
- Required accessories: VAC senso T (P/N 591-00350-00) and vacuum valve
|
- For your protection against splashing water and steam, the operating panel is located below the bath
- All heating baths feature non-slip safety handles to prevent scalding
- Heating bath is constructed of an insulated double wall for your protection against burns and scalding
- Non-sticking vapor tube removes easily eliminating broken glass
- Flask ejector presses off sticking evaporation flasks
- Adjust and fix the height of your evaporation flask in just seconds
- Unique large bore vapor tube offers faster distillation rates
- Long life graphite filled PTFE vacuum seal
- Your choice of manual or motor lift
|
|
LR4010
旋转蒸发仪 |
 |
|
- Rotary Evaporator with all the general advantages
- Digital display for rotation speed, vapor temperature and bath temperature
- Convenient large dial controls for adjustment of rotation speed and heating bath temperature
- Rotation speed from 20 to 270 rpm
- Individual power switches for control panel and heating bath offers additional safety
- One heating bath for water and oil 20 °C - 180 °C
- Digital bath temperature display as standard
- Set bath temperature on display, accuracy +/- 1 °C
- Digital display for vapor temperature +/- 0.1 °C (Vapor temperature sensor refer to accessories)
- Attachment for optional vacuum valve or Woulff bottle
- Upgrade this model with the optional Vacuum controller, VAC control automatic, for automated distillation
|
- For your protection against splashing water and steam, the operating panel is located below the bath
- All heating baths feature non-slip safety handles to prevent scalding
- Heating bath is constructed of an insulated double wall for your protection against burns and scalding
- Non-sticking vapor tube removes easily eliminating broken glass
- Flask ejector presses off sticking evaporation flasks
- Adjust and fix the height of your evaporation flask in just seconds
- Unique large bore vapor tube offers faster distillation rates
- Long life graphite filled PTFE vacuum seal
- Your choice of manual or motor lift
|
|
LR4011
旋转蒸发仪 |
 |
|
- Rotary Evaporator with all the general advantages
- Digital display for rotation speed, vapor temperature and bath temperature
- Convenient large dial controls for adjustment of rotation speed and heating bath temperature
- Rotation speed from 20 to 270 rpm
- Individual power switches for control panel and heating bath offers additional safety
- One heating bath for water and oil 20 °C - 180 °C
- Digital bath temperature display as standard
- Set bath temperature on display, accuracy +/- 1 °C
- Digital display for vapor temperature +/- 0.1 °C (Vapor temperature sensor refer to accessories)
- Attachment for optional vacuum valve or Woulff bottle
Upgrade this model with the optional Vacuum controller, VAC control automatic, for automated distillation |